Tangra TANGRA EVB HIE

High efficiency heat recovery ventilation units TANGRA EVB HiE
 

 

Airflow up to

4400m3/h
  

 

Quick navigation to product sections
 

 

Product description

Maintaining the climat in premises, with minimum energy consumption is major factor in operation cost management of the buildings. High efficiency heat recovery installations provide fresh air supply  with temperature, similar to that  in the room. The need of additional heater is minimized.

 

 

 

 

 

Product range

Product range offers 12 models with air flow from 150 to 4400 m3/h

Heat recovery units could be designed as monoblock or split units allowing easy transport and installation.
According to the room specification, they could be produced for horizontal or vertical installation.


 

Application
 
Personal homes and appartments
 
Offices
 
Trade centers
 
Hotels and restaurants
 
Small industrial workshops
 

 

Annual division of energy costs

 

 

 

Why high efficiency heat recovery?
Heat recovery in ventilation systems is an exceptionally profitable investment. It becames more clear from the comparison between system with crossflow and high efficiency counterflow heat exchanger. The payback period is between 1 and 3 years, depending on the running time of the system.
 

 

Acoustic data
Model/Hz 63 125 250 500 1000 2000 4000 8000
EVB 02 HiE 41 50 50 55 59 57 56 55
EV8 04 HiE 46 57 57 62 66 65 65 64
EV8 06 HiE 47 56 61 66 67 65 64 62
EV8 10 HiE 47 56 61 66 67 65 64 62
EVB 12 HiE 46 59 67 72 76 74 70 60
EVB 16 HiE 47 59 68 73 77 75 71 61
EVB 20 HiE 47 59 68 73 77 75 71 61
EVB 24 HiE 48 57 64 69 74 74 72 63
EVB 30 HiE 51 62 69 70 75 76 71 64
EVB 36 HiE 55 66 72 74 79 78 75 67
EVB 42 HiE 55 66 72 74 79 78 75 67

 * These values are measured at the fan exit at maximum speed

 

 

TECHNICAL SPECIFICATIONS
Model EVB 02 HIE
 

 

 
Absorbed power [W] 2 x 27
Voltage [V] 230
Operation temperature [ C⁰] -40 C0 ÷ 80 C0
Nominal abs. current [A] 2 x 0.27
Level of protection IP 54
Pre-heater capacity [kW]* 0.75
Additional heater capacity [kW]* 0.75

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

 

Model EVB 04 HIE
 

Absorbed power [W] 2 x 180
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 0.85
Level of protection IP 44
Pre-heater capacity [kW]* 1.5
Additional heater capacity [kW]* 1.5

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 06 HIE
 

Absorbed power [W] 2 x 300
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 55 C0
Nominal abs. current [A] 2 x 1.38
Level of protection IP 44
Pre-heater capacity [kW]* 1.5
Additional heater capacity [kW]* 1.5

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 08 HIE
 

Absorbed power [W] 2 x 300
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 55 C0
Nominal abs. current [A] 2 x 1.38
Level of protection IP 44
Pre-heater capacity [kW]* 2.25
Additional heater capacity [kW]* 2.25

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 10 HIE
 

Absorbed power [W] 2 x 300
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 55 C0
Nominal abs. current [A] 2 x 1.38
Level of protection IP 44
Pre-heater capacity [kW]* 2.25
Additional heater capacity [kW]* 2.25

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 12 HIE
 

Absorbed power [W] 2 x 373
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 3.65
Level of protection IP 20
Pre-heater capacity [kW]* 3
Additional heater capacity [kW]* 3

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 16 HIE
 

Absorbed power [W] 2 x 373
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 3.65
Level of protection IP 20
Pre-heater capacity [kW]* 3
Additional heater capacity [kW]* 3

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

 

Model EVB 20 HIE
 

Absorbed power [W] 2 x 373
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 3.65
Level of protection IP 20
Pre-heater capacity [kW]* 4.5
Additional heater capacity [kW]* 4.5

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

 

Model EVB 24 HIE
 

Absorbed power [W] 2 x 373
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 3.58
Level of protection IP 20
Pre-heater capacity [kW]* 4.5
Additional heater capacity [kW]* 4.5

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.

Model EVB 30 HIE
 

Absorbed power [W] 2 x 550
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 4.6
Level of protection IP 20
Pre-heater capacity [kW]* 6
Additional heater capacity [kW]* 6

  * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request.


Model EVB 36 HIE
 

Absorbed power [W] 2 x 750
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 7.80
Level of protection IP 20
Pre-heater capacity [kW]* 9.9
Additional heater capacity [kW]* 9.9

  * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request. The fans are wth 3 speed motors. Please consult the speed controller

Model EVB 42 HIE
 

Absorbed power [W] 2 x 750
Voltage [V] 230
Operation temperature [ C⁰] 20 C0 ÷ 40 C0
Nominal abs. current [A] 2 x 7.80
Level of protection IP 20
Pre-heater capacity [kW]* 9.9
Additional heater capacity [kW]* 9.9

 * Power supply 380V, 3phase +N+PE/50Hz. 230V is also possible on request. The fans are wth 3 speed motors. Please consult the speed controller

 

 

 


Technical information

  • Technical details
  • Product photos
  • Video
  • Files to download
Applications
  • Single family houses
  • Flats/ Apartments
  • Public buildings
  • Schools and Universities
  • Green buildings
  • Offices
  • Hotels
  • Retail
  • Car showroom and parks
  • Agricultural facilities
  • Factories
Elements
  • Cross-flow heat exchanger
Type
  • Plug and play
  • TANGRA Smart control
  • Heat recovery
  • Energy saving